APC
Smart-UPS® RT

|
|
|

|
|
Versatile, high density
power protection for computer Networks
telecommunications, and industrial applications
Smart-UPS RT is a family of high preformance UPSs for servers,
networking equipment, telecommunication systems, industrial and medical
equipment, and other mission-critical applications. Smart-UPS RT UPSs are
based on the field-proven, industry-leading Smart-UPS functionality, but
features double conversion on-line topology, which delivers tight voltage
and frequency regulation, zero transfer time to and from battery, and input
power factor correction. While offering advanced performance and high
availability features, the Smart-UPS RT can be managed using PowerChute
software, as well as an array of SmartSlot accessories. Smart-UPS RT
provides battery back up to the load through the use of internal batteries.
However, an unlimited number of external battery packs can be added to meet
desired levels of runtime. All Smart-UPS RTs and battery packs ship in
tower configuration, while easily converting to the 19" rack-mount
mode with the addition of an APC Rail Kit.

|
|
|

|
|
|
|

|
|
Availability
Double Conversion On-Line
No interruption for your mission critical applications
when the UPS transfers to and from the batteries.
Continuous Voltage and Frequency Regulation
Smart-UPS RT provides premium, regulated sine-wave power
for the sensitive loads. This unit is also compatible with generator set
where it takes in raw power and puts out premium, regulated sine-wave
power.
Wide input voltage range
A 160-280 VAC input voltage range, at full load, means
less time on battery while preserving the battery capacity for blackout
conditions. The input voltage to the UPS can go as low as 100 VAC, at
lighter loads without using the batteries, and still provide conditioned
utility power to the load.
Scalable Run Time
Unlimited number of matching battery packs can be added
to increase the runtime to the desired amount.
Built-in automatic bypass
Ensures seamless power to the loads even in the event of
an electronics failure or an overload condition
Hot Swap Batteries
Ensures continuous operation of the load even when the
batteries are being replaced
Downloadable Firmware
Makes the UPS field-upgradeable
Cold-start
You can power on the unit without any input power. This
provides temporary emergency battery power when the utility power is out.
Intelligent Battery Management
Micro-processor controlled battery charging and
diagnostic testing ensures maximum battery life.
Faster Recharge Time
The Smart-UPS battery charging system is microprocessor
controlled to precisely charge batteries in less time than legacy UPS
systems. This makes your system available more quickly for subsequent power
disturbances.
Manageability
Audible Alarms
Actively let you know if the unit is on battery, if the
battery is low or if there is an overload condition.
Status Indicator LED's
Provides operational status information of the UPS at a
glance. Does not require the use of a computer. Bar meters and status
indicators are simple to use and easy to understand.
Automatic Self Test
The product automatically performs a self-test every two
weeks. This ensures you will be alerted to degraded batteries before they
wear out. Through software, or the push of a button, you may perform
self-tests anytime.
Load Meter
The Load Meter prevents you from exceeding the UPS
capacity. The Volt Meter reports utility line voltage and battery capacity,
allowing you to gauge how much time remains before the batteries are
depleted. An alarm sounds when batteries are low allowing you to save data
and shutdown your system.
Built-in SmartSlot
Choose from various management cards to customize your
UPS and increase overall system availability. Options include; out-of-band
management and remote power off. SmartSlot management cards are sold
separately.
Software
PowerChute Business Edition, departmental-level UPS
management software, provides safe system shutdown and UPS management for
servers and workstations.
Network Management
UPS Network Management Card with Environmental Monitoring
provides management of the UPS by connecting directly to the network via
web browser, Telnet or SSH. Notification features inform you of problems as
they occur. For protected servers, graceful unattended shutdown software is
provided.
Terminal Mode Programmability
Terminal mode is a menu-driven interface that allows for
quick and easy configuration of the UPS. This interface can be accessed
using a computer and a common serial communication application, such as
Hyperterminal. Terminal mode is ideal for customers who are not using
PowerChute plus or a management card.
Adaptability
Rack/Tower Convertible
The UPS has a flexible form factor enabling it to be
installed into a variety of user environments
1:1 and 3:1 Combo in a Single Product
This feature allows the same product to be wired either
to a single phase input or a three phase input. Available in only Smart-UPS
RT 7500/10000 VA models.
Multiple Output Voltages
The 230V nominal output voltage can be programmed for 220V
or 240V operation.
Programmable Frequency
This UPS automatically provides 50 or 60 Hz, and can be
user-set to either value, including desired tolerances.
Downloadable Firmware Makes the UPS field-upgradeable.
Protection
Lightning and Surge Protection
When measured via ANSI/IEEE 587 Category ''A" and
"B" tests, the suppression performance of the APC Smart-UPS is
superior to virtually all separate surge suppressors.
Network-grade line conditioning
Full time EMI/RFI filters prevent line noise from causing
data errors
Sine-wave output
Sine-wave output provides assurance of compatibility with
all types of loads.
Unattended Safe & Graceful Shutdown
Prevents possible data corruption by performing graceful,
unattended operating system shutdown in the event of an extended power
outage.
EPO
Attach the device to an Emergency Power Off (EPO) system
so that power can be turned off in an emergency situation.
Economy
Input Power Factor Correction
Reduced utility and wiring costs. Increasingly a
legislative or specification requirement.
|
|
|
APC
Smart-UPS® VT
|
|
|

|
|
Performance power
protection with scalable runtime for small data centers(10 to 40kVA (30kVA
in 208V))
Over 10 million installed - now available in
three-phase
Smart-UPS VT offers centralized three-phase power protection
with the reliability of the award winning Smart-UPS family. Ideal for small
data centers, large retail stores, regional offices, and dense power
requirements, the Smart-UPS VT includes dual-mains input, automatic and
maintenance bypasses, and scalable runtime with hot-swappable batteries for
increased availability. Low cost of ownership is achieved through
best-in-class efficiency and a reduction in rating of electrical
infrastructure - wires, transformers, and generators due the Smart-UPS VT's
Soft Start feature. APC's Network Management Card with temperature
monitoring provides remote monitoring and management through a simple Web/SNMP
interface and provides integration with ISX Manager. Serviceability is
greatly enhanced by user-replaceable batteries, manageable extended run
frames and included startup and standard onsite warranty services. All
these features make the Smart-UPS VT is the easiest UPS in its class to
deploy, manage and maintain.

|
|
|

|
|
|
|

|
|
Availability
Dual mains input
Increases availability by allowing the UPS to be
connected to two separate power sources.
Scalable runtime
Allows additional run time to be quickly added as needed.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment
while batteries are being replaced.
Generator compatible
Ensures clean, uninterrupted power to protected equipment
when generator power is used.
Automatic internal bypass
Supplies utility power to the connected loads in the
event of a UPS overload condition or fault.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to
perform upgrades and replacements of the batteries reducing Mean Time to
Repair (MTTR) .
Battery replacement without tools
Provides reduced risk of load disruption by allowing
quick and easy battery replacement.
Automatic self-test
Periodic battery self-test ensures early detection of a
battery that needs to be replaced.
Shippable with modules installed
Enables pre-installation UPS staging and testing and
faster installation
Modular design
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, field-replaceable modules.
Manageability
Network manageable
Provides remote management of the UPS over the network.
InfraStruXure Manager compatible
Enables centralized management via APC's InfraStruXure
Manager.
LCD display
Manage the UPS locally through a text-based display that
allows quick diagnosis via stored alarm conditions and events.
Audible alarms
Provides notification of changing utility power and UPS
conditions.
Programmable frequency
Ensures compatibility with different input frequencies.
LED status indicators
Quickly understand UPS status with indicators.
SmartSlot
Customize UPS capabilities with management cards.
Total Cost of Ownership
Input power factor correction
Minimizes installation costs by enabling the use of
smaller generators and cabling.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage
according to battery temperature.
Manual maintenance bypass
Reduces installation costs by eliminating the need for an
external mechanical bypass
Intelligent battery management
Provides higher availability through intelligent
precision-charging that maximizes battery performance, life, and
reliability.
Protection
Frequency and voltage regulation
Preserves battery life and maximizes run time by correcting
poor frequency and voltage conditions without discharging the battery.
Safety-agency approved
Ensures the product has been tested and approved to work
safely with the connected service provider equipment and within the
specified environment. UL, FCC, CE, C-Tick approvals
Cold-start capable
Provides temporary battery power when the utility power
is out.
|
|
|
APC
Silcon 10 kW – 480 kW
|
|
|

|
|
3 Phase Delta Conversion
Online Technology

>> Lowest dimension
>> Lowest total cost
>> Turn key solution
>> Highest Availability
>> Maintenenance bypass switch
>> Awarded client service quality
>> Delta Conversion Technology
>> Input harmonic distortion < % 5
>> Perfect Input power factor Cos 1
>> Ability to work N+1, N+2 redundant
>> Perfect output power factor kVA= kW
>> Extraordinary monitoring software
>> Paralellable until 4 equipment with
"0" cost
>> Highest online efficieny in the world, % 97
>> The best generator compatibility in the world
|
|
|

|
|

The APC Silcon Series has the load capacity to serve a
broad range of electrical equipment - from mainframe computers to Large
Corporation-wide installations, production lines, electronic control
systems and telecommunication equipment. Up to nine Silcon units can be
paralleled to serve special demands for power upgrading or redundancy
|
|
|

|
|
|
|

|
|
Economy
Input Power Factor Correction
The APC Silcon Series is power factor corrected on the
input side, which ensures that the input power factor is always 1
regardless of load and mains voltage. This considerably reduces
installation costs by allowing the use of smaller cables and smaller fuses.
In addition, the APC Silcon Series reduces the costs associated with
generator back-up, as input power factor correction eliminates the need for
oversizing the generator.
Delta Conversion On-line Technology
The APC Silcon Series provides an economic approach to
power protection strategies featuring efficiencies up to 96.5%. The on-line
efficiency translates directly into reduced operating costs by minimizing
heat loss and consequently lowering both electricity and air conditioning
consumption.
Full-rated Power with kVA equaling kW
The full-rated inverter of the APC Silcon Series is a
perfect match for today's power-factor corrected computer loads,
eliminating the need for an oversized UPS.
Temperature Compensated Battery Charging
Temperature Compensated Battery Charging provides
prolonged battery life by regulating the charge voltage according to actual
battery temperature.
Availability
Built-in static bypass switch
The built-in static bypass switch enables the UPS to
transfer the load to utility power, without interruption, in case of heavy
overload or faulty conditions.
200% overload capability
The APC Silcon Series has the ability to supply 200%
overload in normal operation for a period of 60 seconds. This enables the
system to handle inrush currents, sudden peak loads and output faults
without transitioning to bypass. The result is increased availability.
Paralleling Features for Capacity and Redundancy
If required for capacity or redundancy, APC Silcon Series
can easily be expanded by paralleling units. Up to four units can be
configured in parallel without the need for an external control cabinet.
For even higher power requirements or redundancy a total of up to nine
units can be paralleled to supply the load.
Manageability
Intelligent Battery Management
The APC Silcon Series features intelligent battery
monitoring and temperature-compensated battery charging. Battery data is
continuously compared to pre-programmed data in the monitoring software to
ensure reliable batteries. A reduction in battery capacity automatically
triggers an alarm.
Smart Slot
Choose from various management cards to customize your
UPS and increase overall system availability. Options include; out-of-band
management and remote power off. SmartSlot management cards are sold
separately.
Network Management
UPS Network Management Card with Environmental Monitoring
provides management of the UPS by connecting directly to the network via
web browser, Telnet or SSH. Notification features inform you of problems as
they occur. For protected servers, graceful unattended shutdown software is
provided.
Multiple System Shutdown
Provides graceful, unattended shutdown for the connected
servers should an extended power outage occur.
Protection
Designed and manufactured under ISO9001 / ISO14001 certification
APC's solution complies with ISO 9001 Quality standards,
and ISO 14001 Environmental stan
|
|
|
Symmetra
® MW
|
|
|

|
|
High performance,
redundant power protection with scalable power and runtime for data centers
and facilities (400kW to 1.6MW)
Think big, think scalable - The world's largest modular UPS
Symmetra MW redefines high-power UPS technology as a modular,
fault-tolerant UPS in the 400-1600 kilowatt range. Ideal for large data
centers, complete buildings, healthcare and other critical facility
protection requirements, the Symmetra MW can be scaled for rigorous and
changing electrical demands. Symmetra MW provides increased availability
through internal N+1 configurability, predictive failure notification and
multi-module paralleling features. Setting a new standard for low cost of
ownership Symmetra MW delivers best-in-class efficiency and a reduction in
rating of electrical infrastructure- wires, transformers and generators.
Slide-in/out power modules, manageable external batteries and
self-diagnosing features greatly reduce mean time to repair. Combined with
a wide range of line-up and match options Symmetra MW provides a
customizable system in a standardized design for any large on-demand
network-critical physical infrastructure.

|
|
|

|
|
|
|

|
|
Availability
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing
configuration with one more Power Module than is necessary to support the
connected load.
Power Modules connected in parallel
Enhances availability by allowing immediate, seamless
recovery from isolated module failures
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Modular design
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, field-replaceable modules.
Predictive failure notification
Provides early-warning fault analysis on batteries
enabling timely preventive maintenance
LCD display
Provides schematic overview of critical data for guided
operation and troubleshooting on color LCD touch-screen.
Audible alarms
Provides notification of changing utility power and UPS
conditions.
Network manageable
Provides remote management of the UPS over the network.
Generator compatible
Ensures clean, uninterrupted power to protected equipment
when generator power is used.
Agility
Scalable power capacity
Increases availability by allowing a trained user to
perform upgrades and replacements of the batteries reducing Mean Time to
Repair (MTTR) .
Scalable runtime
Provides reduced risk of load disruption by allowing
quick and easy battery replacement.
Parallel-capacity capable
Periodic battery self-test ensures early detection of a
battery that needs to be replaced.
Parallel-redundant capable
Enables pre-installation UPS staging and testing and
faster installation
Multiple cable-entry points
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, field-replaceable modules.
Front-access servicing
Simplifies installation and maintenance while minimizing
space requirements
Total Cost of Ownership
Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS
for Power Factor Corrected (PFC) loads. .
Input power factor correction
Eliminates the need for an external phase-compensation
unit and minimizes installation costs by enabling the use of smaller
generators and cabling.
Automatic self-test
Periodic battery self-test ensures early detection of a
battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage
according to battery temperature.
Manageable external batteries
Reduces preventative maintenance service needs by
monitoring the health and status of the external batteries and their
expected runtime.
Intelligent battery management
Provides higher availability through intelligent
precision-charging that maximizes battery performance, life, and
reliability.
|
|
|
Symmetra®
PX
|
|
|

|
|
|
|

|
|
|
|

|
|
Availability
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing
configuration with one more Power Module than is necessary to support the
connected load
Redundant Intelligence Modules
Provides higher availability to the UPS connected loads
by giving redundant communication paths to critical UPS functions.
Power Modules connected in parallel l
Enhances availability by allowing immediate, seamless
recovery from isolated module failures.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment
during Power Module replacement.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment
during Intelligence Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment
while batteries are being replaced
Modular design
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, field-replaceable modules.
Network manageable
Provides remote management of the UPS over the network.
Automatic internal bypass
Supplies utility power to the connected loads in the
event of a UPS overload condition or fault.
Agility
Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick
upgrades later.
Scalable runtime
Allows additional run time to be quickly added as needed.
User-replaceable power modules
Enables simple upgrades and replacements of the Power
Modules.
User-replaceable intelligence modules
Enables simple upgrades and replacements of the
Intelligence Modules
User-replaceable batteries
Increases availability by allowing a trained user to
perform upgrades and replacements of the batteries reducing Mean Time to
Repair (MTTR)
Front-access servicing
Simplifies installation and maintenance while minimizing
space requirements.
Programmable frequency
Ensures compatibility with different input frequencies.
SmartSlot
Customize UPS capabilities with management cards.
Battery replacement without tools
Allows quick, easy battery replacement.
Total Cost of Ownership
Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS
for Power Factor Corrected (PFC) loads.
Input power factor correction
Minimizes installation costs by enabling the use of
smaller generators and cabling.
Automatic self-test
Periodic battery self-test ensures early detection of a
battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage
according to battery temperature.
Manageable external batteries
Reduces preventative maintenance service needs by
monitoring the health and status of the external batteries and their
expected runtime.
Intelligent battery management
Provides higher availability through intelligent precision-charging
that maximizes battery performance, life, and reliability.
Generator compatible
Ensures clean, uninterrupted power to protected equipment
when generator power is used.
Manageability
InfraStruXure Manager compatible
Enables centralized management via APC's InfraStruXure
Manager.
LCD display
Manage the UPS locally through a text-based display that
allows quick diagnosis via stored alarm conditions and events
LED status indicators
Quickly understand UPS status with indicators.
Audible alarms
Provides notification of changing utility power and UPS
conditions
|
|
|
Symmetra®
LX

|
|
|

|
|
High performance,
redundant power protection with scalable power and runtime for
space-constrained server rooms, and voice and data networks.
(4-16kVA N+1 Redundant Rack/Tower Convertible 13U-19U, 4-16kVA N+1
Redundant Extended Run Tower)
Industry’s most space-optimized modular UPS solutions
Engineered to deliver the highest level of business continuity
possible, the Symmetra LX uses a modular, redundant architecture that can
scale power and runtime as demand increases or when higher levels of
availability are required. With built-in network manageability, and
rack-optimized and tower models available from 4-16 kVA N+1 redundant, the
online Symmetra LX is the choice to protect high-performance IT and Telecom
equipment in business-critical server and network rooms. A flexible
rack/stack design offers unmatched runtime and power capacity in space
constrained environments. Symmetra LX allows incredibly fast upgrades and
maintenance with virtually all of its parts contained in field-swappable
components. These include hot-swappable, user-replaceable power, battery,
and intelligence modules, management cards, LCD display, fans, and external
battery frames. Additionally the wiring tray, frame electronics,
receptacles, and casters can be swapped in minutes if necessary. Symmetra
LX achieves industry-leading footprint or U-space needed in an equipment
rack, increased speed and ease of deployment, and reduced repair time.

|
|
|

|
|
|
|

|
|
Availability
Modular design
Provides fast serviceability and reduced maintenance
requirements via self-diagnosing, field-replaceable modules.
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing
configuration with one more Power Module than is necessary to support the
connected load.
Redundant Intelligence Modules
Provides higher availability to the UPS connected loads
by giving redundant communication paths to critical UPS functions.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment
during Intelligence Module replacement.
Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment
during Power Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment
while batteries are being replaced
Power Modules connected in parallel
Enhances availability by allowing immediate, seamless
recovery from isolated module failures.
Battery modules connected in
parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the
event of a UPS overload condition or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the
return of utility power.
Adaptability
Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick
upgrades later.
Scalable runtime
Allows additional run time to be quickly added as needed.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when
adding extra runtime to the UPS.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating
from tower to rack-mount environment.
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different
plug types.
Programmable frequency
Ensures compatibility with different input frequencies.
Manageability
Manageable external batteries
Reduces preventative maintenance service needs by
monitoring the health and status of the external batteries and their
expected runtime.
Network manageable
Monitor and control the UPS and access environmental
information remotely via the embedded APC Network Management Card with
temperature monitoring.
InfraStruXure Manager compatible
Enables centralized management via APC's InfraStruXure
Manager.
LCD display
Manage the UPS locally through a text-based display that
allows quick diagnosis via stored alarm conditions and events.
Intelligent battery management
Maximizes battery performance, life, and reliability
through intelligent, precision charging.
SmartSlot
Customize UPS capabilities with management cards.
Serviceability
Shippable with modules installed
Enables pre-installation UPS staging and testing and faster
installation.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive
component replacement.
Automatic self-test
Periodic battery self-test ensures early detection of a
battery that needs to be replaced.
Audible alarms
Actively let you know if the unit is on battery, if the
battery is low or if there is an overload condition
User-replaceable intelligence modules
Enables simple upgrades and replacements of the
Intelligence Modules.
User-replaceable power modules
Enables simple upgrades and replacements of the Power
Modules.
User-replaceable batteries
Increases availability by allowing a trained user to
perform upgrades and replacements of the batteries reducing Mean Time to
Repair (MTTR)
Disconnected battery notification
Warns when a battery is not available to provide backup
power.
Removable input/output wiring tray
Allows quick and easy installation and maintenance of the
UPS.
Protection
Power conditioning
Protects connected loads from surges, spikes, lightning,
and other power disturbances.
Frequency and voltage regulation
Gives higher application availability by correcting poor
frequency and voltage conditions without using the battery.
Input power factor correction
Minimizes installation costs by enabling the use of
smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to the loads in the
event of an extended power outage
Cold-start capable
Provides temporary battery power when the utility power
is out.
Resettable circuit breakers
Enables quick recovery from UPS overload events.
Safety-agency approved
Ensures the product has been tested and approved to work
safely with the connected service provider equipment and within the
specified environment. UL, FCC, CE, C-Tick approvals.
|
|
|
|
|